TEL: 0904251826
Icon Collap
Trang chủ » Tất cả sản phẩm » Switch công nghiệp quản lý Layer 2 8 cổng Gigabit Ethernet +2 cổng quang Gigabit SFP + 2 cổng quang 2.5G SFP 3Onedata IES6300-8GT2GS2HS-2P48
Thumb Product

Switch công nghiệp quản lý Layer 2 8 cổng Gigabit Ethernet +2 cổng quang Gigabit SFP + 2 cổng quang 2.5G SFP 3Onedata IES6300-8GT2GS2HS-2P48

Model : IES6300-8GT2GS2HS-2P48
Lượt truy cập: 1371 Lượt xem

Support 2 2.5G Ethernet SFP fiber ports, 2 Gigabit SFP fiber ports (optional), 4/8 Gigabit copper ports (optional PoE), 2 input I/O ports and 2 output I/O ports (optional)

Adopt Ring patented technology, support single ring, coupling ring, chain, Dual-homing network function

Support 4 optional power supplies: 24VDC PoE, 48VDC PoE, 12~48VDC non-PoE and 220VAC non-PoE 

Support -40~75℃ wide operating temperature range

Chia sẻ:

Switch công nghiệp quản lý Layer 2 8 cổng Gigabit Ethernet +2 cổng quang Gigabit SFP + 2 cổng quang 2.5G SFP 3Onedata IES6300-8GT2GS2HS-2P48

IES6300 Series are 12/8/6-port full Gigabit layer 2 managed industrial Ethernet switches with optional PoE. PoE power supply conforms to IEEE 802.3af/at protocol standard. This series provide 34 products and support a variety of interfaces including Gigabit copper ports, Gigabit PoE copper ports, Gigabit SFP slots, 2.5G SFP slots and I/O ports. They adopt DIN-Rail mounting or wall mounting to meet the requirements of different application scenes.

Network management system supports various network protocols and industrial standards, such as Ring, STP/RSTP/MSTP, ERPS, DHCP, VLAN, QoS function, IGMP Snooping, LLDP, GVRP, Port Trunking, Port Mirroring, etc. It also possesses complete management functions, including Port Configuration, Access Control, AAA Service, Network Diagnosis, Online Upgrading and so on, and supports CLI, WEB, Telnet, SSH, SNMP and other access methods. It can provide users with good experience with friendly design of network management system interface, simple and convenient operation.

This product supports four optional power supplies. The dual power supply product has two independent power supply circuits which can ensure the normal operation of the device when one power supply fails. The design of DIP switch could implement device factory setting recovery. When DC power supply or port has link failure, ALM indicator will be bright and send out alarm, meanwhile, alarm device connected to the relay will send out alarm for rapid scene troubleshooting. The hardware adopts fanless, low power consumption and wide temperature and voltage design, which has passed rigorous industrial standard tests, and suits for the industrial scene environment with harsh requirements for EMC. It can be widely used in AP coverage, railway transportation, smart city, safe city, new energy, smart grid, aerospace, intelligent manufacturing, military project and other industrial fields.

Features and Benefits

 SNMPv1/v2c/v3 is used for network management of various levels

 RMON can be used for efficient and flexible network monitoring

 QoS supports real-time traffic classification and priority setting

 LLDP can achieve automatic topology discovery, which is convenient for visual management

 DHCP server and DHCP client could be used for allocating IP address of different strategies

 DHCP Snooping can ensure DHCP client gets IP address from legal DHCP server

 DHCP relay function can realize IP address, gateway, DNS configuration cross network segment 

 File management is convenient for the device rapid configuration and online upgrading

 User privilege classification configuration can set user privilege level

 SSH configuration and HTTPS configuration can improve device’s management security and guarantee data access security 

 Support AAA service, which can provide security assurance for various services

 IPMC file configuration can deploy access control on IP multicast flow

 MVR configuration supports multicast communication forwarding on multicast VLAN

 EPS configuration can realize network status monitor

 EVC configuration function can realize the connection between the two points of Ethernet service

 MEP function can determine the scope and boundary of maintenance domain

 Ring and STP/RSTP/MSTP can achieve network redundancy, preventing network storm

 EPRS function can realize link backup and improve the reliability of network

 Relay alarm is convenient for troubleshooting of construction site

 Storm suppression can restrain broadcast, unknown multicast and unicast

 VLAN is used for simplifying network planning

 Private VLAN function could achieve port isolation in the same VLAN and save Vlan resources

 Voice VLAN function can improve the priority of voice flow transmission for user to ensure the quality of call

 GVRP configuration could be used for registering and unregistering VLAN properties

 Port Trunking and LACP can increase network bandwidth and enhance the reliability of network connection to achieve optimum bandwidth utilization

 IGMP Snooping can be used for filtering multicast traffic to save the network bandwidth

 MLD Snooping could be used for managing and controlling IPv6 multicast group

 PTP click settings can realize a highly precise time synchronization

 Link OAM function can monitor the health of the network and locate faulted link and fault conditions

 VCL function can divide VLAN based on MAC address, protocol, and IP subnet.

 PoE could power device over Ethernet, thus decreasing the cable connection of powered devices

 Support I/O port input and output, I/O status alarm and control remote device

 Support DDM (digital diagnostic monitoring) function, which can monitor the optical power, temperature and other real-time parameters of SFP fiber module with DDM function, facilitating the link default diagnosis of optical fiber

Standard & Protocol IEEE 802.3 for 10Base-T

IEEE 802.3u for 100Base-TX

IEEE 802.3ab for 1000Base-T

IEEE 802.3z for 1000Base-X

IEEE 802.3x for Flow Control

IEEE 802.1D for Spanning Tree Protocol

IEEE 802.1w for Rapid Spanning Tree Protocol

IEEE 802.1s for Multiple Spanning Tree Protocol

ITU-T G.8032 for ERPS

IEEE 802.1Q for VLAN

IEEE 802.1p for CoS

IEEE 802.1AB for LLDP

IEEE 802.3ad for LACP

IEEE 802.3af for PoE

IEEE 802.3at for PoE+

Management SNMP v1/v2c/v3 Centralized Management of Equipment, QoS, PoE, DHCP Server, DHCP Snooping, DHCP Relay, Static MAC Address, LLDP, Storm Suppression, User Password, Login Method, File Management, Log Management, Port Statistics
Security User Privilege Classification, Authentication Method Configuration, SSH Configuration, HTTPS Configuration, Access Control, SNMP, RMON, Port Limit Control, Port Security, NAS, ACL, Ethernet Services, RADIUS Server Authentication, TACACS + Server Authentication, Port Alarm, DC Power Supply Alarm, IO Alarm, Loop Protection
Switch Function 802.1Q VLAN, Static Aggregation, LACP
Unicast / Multicast IGMP Snooping, Unicast MAC
Redundancy Technology Ring, STP/RSTP/MSTP, ERPS
Troubleshooting Ping, Cable Detection, DDMI, Port Mirroring
Time Management NTP, Time Zone Configuration
PoE (optional) The maximum power of PoE port: 30W

The power supply pin of PoE: V+, V+, V-, V- correspond to Pin 1, 2, 3, 6

Interface Gigabit Copper Port: 10/100/1000Base-T(X), RJ45, Automatic Flow Control, Full/Half Duplex Mode, MDI/MDI-X Autotunning, optional PoE

Gigabit SFP Slot : 100/1000Base-X self-adaption or forced mode, SFP slot

2.5G SFP Slot: 100/1000/2.5GBase-X self-adaption or forced mode SFP slot

I/O port (optional): Support 2 inputs and 2 outputs, 8-pin 3.81mm pitch terminal blocks, support dry contact input, relay-type output

Console port: CLI command line management port(RS-232), RJ45

Alarm Port: 6-pin 5.08mm pitch terminal blocks, relay occupies 2 pins and 1 relay alarm information output is supported, the current load capability is 1A@30VDC or 0.3A@125VAC

Indicator Running indicator, alarm indicator, power supply indicator, interface indicator, PoE indicator (optional), I/O output indicator (optional), I/O input indicator (optional)
Switch Property Transmission mode: store and forward

MAC address: 8K

Packet buffer size: 4Mbit

Backplane bandwidth: 30G

Switch time delay: <10μs

Power Supply IES6300-8GT2GS2HS-2P48,

IES6300-8GT2HS-2P48,

IES6300-8GT2GS2HS-2DI2DO-2P48:

Voltage range: 12~48VDC

Connection method: 6-pin 5.08mm pitch terminal blocks (includes 4-pin power supply)

Power supply quantity: dual power supply redundancy backup

Connection protection: non-polarity

Overcurrent protection: 3A

IES6300-8GP2GS2HS-2P24-120W,

IES6300-8GP2HS-2P24-120W:

Power supply range: 24VDC PoE

Connection method: 6-pin 5.08mm pitch terminal blocks (includes 4-pin power supply)

Power supply quantity: dual power supply redundancy backup

Connection protection: anti-reverse connection

Overcurrent protection: 12A

IES6300-8GP2GS2HS-2P48-240W,

IES6300-8GP2HS-2P48-240W,

IES6300-8GP2GS2HS-2DI2DO-2P48-240W:

Power input: 48VDC PoE

Connection method: 6-pin 5.08mm pitch terminal blocks (includes 4-pin power supply)

Power supply quantity: dual power supply redundancy backup

Connection protection: anti-reverse connection

Overcurrent protection: 5A

IES6300-8GP2GS2HS-P220,

IES6300-8GP2HS-P220:

Power input: 220VAC/DC

Connection method: 6-pin 5.08mm pitch terminal blocks (includes 4-pin power supply)

Power Consumption IES6300-8GT2GS2HS-2P48, IES6300-8GT2GS2HS-2DI2DO-2P48:

No-load: ≤ 5.76W@48VDC

Full-load: ≤12W@48VDC

IES6300-8GT2GS2HS-2P48-240W, IES6300-8GT2GS2HS-2P24-120W, IES6300-8GP2GS2HS-2DI2DO-2P48-240W:

No-load: ≤ 5.76W@48VDC

Full-load: ≤ 132W@24VDC (with 120W PoE load)

≤ 252W@48VDC (with 240W PoE Load)

Working Environment Operating temperature: -40~75℃

Storage temperature:-40~85℃

Relative humidity: 5%~95% (no condensation)

Physical Characteristic Housing: IP40 protection, metal

Installation: DIN-Rail or wall mounting

Weight: ≤ 0.78kg

Dimension (W x H x D): 53mm×138mm×110mm

Industrial Standard IEC 61000-4-2 (ESD, electrostatic discharge), Level 3

IEC 61000-4-4 (EFT, electrical fast transient pulses), Level 3

IEC 61000-4-5 (Surge), Level 3

Shock: IEC 60068-2-27

Free fall: IEC 60068-2-32

Vibration: IEC 60068-2-6

Authentication CE, FCC, RoHS

IES6300 Series Datasheet

IES6300 Series QIG

Available Models Gigabit RJ45 LAN Port SFP Slot I/O Port PoE

Power

Power Supply
Non-

PoE

PoE Gigabit 2.5G Input Range Quantity
IES6300-8GT2GS2HS-2P48 8 2 2 12~48VDC 2
IES6300-8GP2GS2HS-2P24-120W 8 2 2 120W 24VDC 2
IES6300-8GP2GS2HS-2P48-240W 8 2 2 240W 48VDC 2
IES6300-8GT2GS2HS-P220 8 2 2 220VAC/DC 1
IES6300-8GT2HS-2P48 8 2 12~48VDC 2
IES6300-8GP2HS-2P24-120W 8 2 120W 24VDC 2
IES6300-8GP2HS-2P48-240W 8 2 240W 48VDC 2
IES6300-8GT2HS-P220 8 2 220VAC/DC 1
IES6300-8GT2GS2HS-2DI2DO-2P48 8 2 2 2 12~48VDC 2
IES6300-8GP2GS2HS-2DI2DO-2P48-240W 8 2 2 2 240W 48VDC 2
Đăng ký nhận bản tin

<